Model 8511

SKU 8511 Categories ,

McMillan RHODIUM Series Flow Controllers are capable of measuring and controlling virtually any clean, dry gas as low as 0 – 50 sccm or as high as 0 – 10 L/min. Repeatable results are achieved using a platinum-based micro-electromechanical system (MEMS) flow rate sensor device that is manufactured with extreme precision to ensure consistent results from unit to unit.

Flow Technology
Product Configurator
Is the Model 8511 right for you? Use our product configurator to build the exact part number required for your application and request a quote with pricing and delivery time.

Description

McMillan RHODIUM Series Flow Controllers are capable of measuring and controlling virtually any clean, dry gas as low as 0 – 50 sccm or as high as 0 – 10 L/min. Repeatable results are achieved using a platinum-based micro-electromechanical system (MEMS) flow rate sensor device that is manufactured with extreme precision to ensure consistent results from unit to unit. 

To actively control flow rate, RHODIUM units leverage a high precision PID controller to control a fast-acting solenoid valve. Analog inputs enable direct, fast, and accurate control of the gas flow. Integrated analog outputs report current flow rate for monitoring and control verification. 

Compared to conventional mass flow controllers, RHODIUM Series Flow Controllers offer smaller size, higher accuracy, larger turn-down ratios, and faster response times. 

Features & Options

MOUNTING

The RHODIUM Series has two female threaded ports on the bottom of the device that accept M4 bolts. An optional mounting plate is available to accommodate installation from the topside.

CALIBRATION

The RHODIUM Series is calibrated in the vertical position. All other positions can cause offset depending on pressure and gas conditions. Flow is unidirectional and must pass through the unit as indicated on the device. All units are calibrated with and for dry nitrogen (N2). Calibration for other gases may be available – please contact the factory.

WIRING

A male 9-pin D-sub connector is provided for all power and signal connections. Optional accessories include a mating cable with pigtail leads (9941-1-2M), a connection block that provides screw-down terminals and a port for a power adapter (9941-3), and 120/240 VAC power adapters that can be used with the connection block (9681-4 or 9691-4).

POWER

RHODIUM Series units require 24VDC power and typically draw less than 250 mA of current.

SIGNAL

Two I/O signal configurations are available: 0-5 VDC or 4-20mA. In either case, the lower end of the range represents zero flow (0 VDC or 4 mA) and the high end of the range represents 100% rated flow (5 VDC or 20 mA).

FLUID CONNECTIONS

Each unit features female SAE 9/16-18 straight thread ports for the inlet and outlet. Optional fittings are available with either ¼” or 3/8” stainless steel (316L) tube connections.

Pin Assignments for DB9 Connector

Diagram of Flow Controller Logic

Optional 8511-MP Mounting Plate

Specifications

Compatible Gases
RHODIUM Series

Flow Range

See Product Configurator for Flow Range Options

Gas Type

Nitrogen (N2)

Calibration Conditions

Temperature: 32 °F [ 0 °C ]

Pressure: 760 mmHG [ 0.001 barg ]

Accuracy

± 1.0% of full scale

Repeatability

± 0.015% of full scale

Response Time

4 ms

Settling Time

150ms

Control Range

2% to 100%

Operating Temperature

32 to 122 ° F [ 0 to 50 ° C ]

Operating Humidity

5 to 95% relative humidity

Pressure Range

Operating: 0 to 130.5 psig [ 0 to 9 barg ]

Burst: 435.1 psig [ 30 barg ]

Leak Tightness

1 x 108 mBar l/s He

Differential Pressure

Min: 7.3 to 43.5 psig [ 0.5 to 3 barg ]

Max: 101.5 psig [ 7 barg ]

Gas Compatibility

Non-corrosive gases

Analog Input

0-5 VDC or 4-20 mA

Analog Output

0-5 VDC or 4-20 mA

Wetted Materials

Aluminum

Silicon

Silicon Nitride

Gold

Platinum

Silicone Die-attach

Epoxy

Stainless Steel

Brass

FKM

Fittings (Optional)

Stainless Steel

9/16-18 SAE

1/4" or 3/8" Tube Fitting with O-Ring Seal

Electrical Information

Voltage Supply DC

Nominal = 24 V ± 10%

Ripple = < 50 mV

Current Supply DC

Typical = < 200 mA

Maximum < 250 mA

Warm-Up Time

Deviation < ± 0.1% of full scale: 3 sec

Optimum Accuracy: 15 min

Analog Output

Resistive Load: > 2 Kohms

Capacitive Load: < 100 nF

Downloads

CategoriesTitleSummaryFile SizeDownload
Model (STP)8511-XX-XX with 9853-9-T6 Fittings

3D model files for RHODIUM (Model 8511) with 9853-9-T6 Fittings

2 MB
Model (STP)8511-XX-XX with 9853-9-T4 Fittings

3D model files for RHODIUM (Model 8511) with 9853-9-T4 Fittings

3 MB
Manuals (PDF)RHODIUM_OM-85X 2405 2

Operating manual for the RHODIUM (Model 8511)

2 MB
Dimensions (PDF)RHODIUM_DD-85X 2405 1

Dimensional drawings for the RHODIUM (Model 8511)

730 KB
Data Sheets (PDF)RHODIUM_DS-85X 2405 6

Latest data sheet for the RHODIUM (Model 8511)

2 MB

Related Products

McMillan Model 50D Mass Flow Meters feature an integrated digital flow rate display and are constructed from aluminum. They are capable of measuring virtually any clean, dry gas as low as 0-20 sccm or as high as 0-500 L/minute.
The 6010-01 features an Integrated Package where all electronics and interfaces are contained in a single case. IRIDIUM is a platform for configurable flow control. Its modular design allows for a single device to adapt to a variety of flow conditions and applications. Standard configurations are available for liquid flow rate regulation. 
McMillan Model 50K Mass Flow Meters are constructed from aluminum and are capable of measuring virtually any clean, dry gas as low as 0-20 sccm or as high as 0-500 L/minute.