Model 101
McMillan Model 101 FLO-SENSORS are capable of measuring extremely low liquid flow rates from 13 mL/minute up to 10 L/minute with a full scale accuracy of ±1.0% or better!
A wide variety of fluids may be measured. Repeatable results are achieved using a patented Pelton-type microturbine wheel. This proven design has been providing precision results since 1988 and has developed a well-deserved reputation for continuous operational service for many years without failure.
Because of the compact size and economical cost of these products, the Model 101 FLO-SENSORS are suitable for a wide variety of industrial, commercial, laboratory and O.E.M. applications. Some sample applications include measurement of hydrocarbon fluids, fuels, light oils, solvents, coolant, pesticides, mild acids, alkalis, and deionized water.
Several power and output configurations are available,including both pulse and analog outputs. NIST Traceable certificates are available.
A power adapter or cable assembly is required for operation.
Model 101 Features & Options
ACCURACY/LINEARITY
All models have a standard accuracy specification of ±1.0% F.S. (including linearity). An improved accuracy specification of ±0.5% F.S. is available. NIST traceable calibration certifications are standard for improved accuracy (suffix H) models and optional for standard units.
DISPLAYS
McMillan has a comprehensive range of FLO-METERS with integrated displays. A number of remote displays are also available for use with any FLO-SENSOR.
ELECTRICAL CONNECTIONS
Most units have an integrated 4-pin male connector. To complete connections, either a cable assembly or power adapter should be ordered. Units where the circuit board has been epoxy potted for increased chemical resistance feature an integrated cable with pigtail leads.
FLOW RANGES
Flow ranges from 13-100 mL/minute up to 1.0-10.0 L/minute are available. Consult the factory for custom requirements.
FLUID CONNECTIONS
All units have compression type tube fittings as standard. Many alternate fitting types and sizes may be selected as allowed in the Product Configurator.
POWER
Most units may be specified to operate with either 12VDC or 24 VDC power. Various power adapters are also available for use with 12VDC versions.
SIGNAL OUTPUTS
Most units may be ordered with a 0-5VDC output or with both 0-5VDC and pulse outputs.
Model 102
McMillan Model 102 FLO-SENSORS are capable of measuring extremely low liquid flow rates from 13 mL/minute up to 10 L/minute with a full scale accuracy of ±1.0% or better!
A wide variety of fluids may be measured. Repeatable results are achieved using a patented Pelton-type microturbine wheel. This proven design has been providing precision results since 1988 and has developed a well-deserved reputation for continuous operational service for many years without failure.
Because of the compact size and economical cost of these products, the Model 102 FLO-SENSORS are suitable for a wide variety of industrial, commercial, laboratory and O.E.M. applications. Some sample applications include measurement of hydrocarbon fluids, fuels, light oils, solvents, coolant, pesticides, mild acids, alkalis, and deionized water.
Several power and output configurations are available,including both pulse and analog outputs. NIST Traceable certificates are available.
A power adapter or cable assembly is required for operation.
102 Features & Options
ACCURACY/LINEARITY
All models have a standard accuracy specification of ±1.0% F.S. (including linearity). An improved accuracy specification of ±0.5% F.S. is available. NIST traceable calibration certifications are standard for improved accuracy (suffix H) models and optional for standard units.
DISPLAYS
McMillan has a comprehensive range of FLO-METERS with integrated displays. A number of remote displays are also available for use with any FLO-SENSOR.
ELECTRICAL CONNECTIONS
Most units have an integrated 4-pin male connector. To complete connections, either a cable assembly or power adapter should be ordered. Units where the circuit board has been epoxy potted for increased chemical resistance feature an integrated cable with pigtail leads.
FLOW RANGES
Flow ranges from 13-100 mL/minute up to 1.0-10.0 L/minute are available. Consult the factory for custom requirements.
FLUID CONNECTIONS
All units have compression type tube fittings as standard. Many alternate fitting types and sizes may be selected as allowed in the Product Configurator.
POWER
Most units may be specified to operate with either 12VDC or 24 VDC power. Various power adapters are also available for use with 12VDC versions.
SIGNAL OUTPUTS
Most units may be ordered with a 0-5VDC output or with both 0-5VDC and pulse outputs.
Model 104
McMillan Model 104 FLO-SENSORS are capable of measuring extremely low liquid flow rates from 13 mL/minute up to 10 L/minute with a full scale accuracy of ±1.0% or better!
A wide variety of fluids may be measured. Repeatable results are achieved using a patented Pelton-type microturbine wheel. This proven design has been providing precision results since 1988 and has developed a well-deserved reputation for continuous operational service for many years without failure.
Because of the compact size and economical cost of these products, the Model 104 FLO-SENSORS are suitable for a wide variety of industrial, commercial, laboratory and O.E.M. applications. Some sample applications include measurement of hydrocarbon fluids, fuels, light oils, solvents, coolant, pesticides, mild acids, alkalis, and deionized water.
Several power and output configurations are available,including both pulse and analog outputs. NIST Traceable certificates are available.
A power adapter or cable assembly is required for operation.
104 Features & Options
ACCURACY/LINEARITY
All models have a standard accuracy specification of ±1.0% F.S. (including linearity). An improved accuracy specification of ±0.5% F.S. is available. NIST traceable calibration certifications are standard for improved accuracy (suffix H) models and optional for standard units.
DISPLAYS
McMillan has a comprehensive range of FLO-METERS with integrated displays. A number of remote displays are also available for use with any FLO-SENSOR.
ELECTRICAL CONNECTIONS
Most units have an integrated 4-pin male connector. To complete connections, either a cable assembly or power adapter should be ordered. Units where the circuit board has been epoxy potted for increased chemical resistance feature an integrated cable with pigtail leads.
FLOW RANGES
Flow ranges from 13-100 mL/minute up to 1.0-10.0 L/minute are available. Consult the factory for custom requirements.
FLUID CONNECTIONS
All units have compression type tube fittings as standard. Many alternate fitting types and sizes may be selected as allowed in the Product Configurator.
POWER
Most units may be specified to operate with either 12VDC or 24 VDC power. Various power adapters are also available for use with 12VDC versions.
SIGNAL OUTPUTS
Most units may be ordered with a 0-5VDC output or with both 0-5VDC and pulse outputs.
Model 107
McMillan Model 107 FLO-SENSORS are capable of measuring extremely low liquid flow rates from 13 mL/minute up to 10 L/minute with a full scale accuracy of ±1.0% or better!
A wide variety of fluids may be measured. Repeatable results are achieved using a patented Pelton-type microturbine wheel. This proven design has been providing precision results since 1988 and has developed a well-deserved reputation for continuous operational service for many years without failure.
Because of the compact size and economical cost of these products, the Model 107 FLO-SENSORS are suitable for a wide variety of industrial, commercial, laboratory and O.E.M. applications. Some sample applications include measurement of hydrocarbon fluids, fuels, light oils, solvents, coolant, pesticides, mild acids, alkalis, and deionized water.
Several power and output configurations are available,including both pulse and analog outputs. NIST Traceable certificates are available.
A power adapter or cable assembly is required for operation.
107 Features & Options
ACCURACY/LINEARITY
All models have a standard accuracy specification of ±1.0% F.S. (including linearity). An improved accuracy specification of ±0.5% F.S. is available. NIST traceable calibration certifications are standard for improved accuracy (suffix H) models and optional for standard units.
DISPLAYS
No displays are currently available for units with a 4-20 mA output.
ELECTRICAL CONNECTIONS
Most units have an integrated 4-pin male connector. To complete connections, either a cable assembly or power adapter should be ordered. Units where the circuit board has been epoxy potted for increased chemical resistance feature an integrated cable with pigtail leads.
FLOW RANGES
Flow ranges from 13-100 mL/minute up to 1.0-10.0 L/minute are available. Consult the factory for custom requirements.
FLUID CONNECTIONS
All units have compression type tube fittings as standard. Many alternate fitting types and sizes may be selected as allowed in the Product Configurator.
POWER
All Model 107 units require 24 VDC power.
SIGNAL OUTPUTS
All Model 107 units feature a non-isolated 4-20 mA current output proportional to flow rate.
Pressure Drop
Fitting Codes
Specifications
- Accuracy (including linearity, best fit straight line):
- Model 101: Standard: ±1.0% Full Scale
H suffix: ±0.5% Full Scale
Model 102: Standard: ±1.0% Full Scale
H suffix: ±0.5% Full Scale
Model 104: Standard: ±1.0% Full Scale
H suffix: ±0.5% Full Scale
Model 107: Standard: ±1.0% Full Scale
H suffix: ±0.5% Full Scale - Repeatability:
- Model 101: Standard: ±0.2% Full Scale
N Suffix: ±0.5% Full Scale
Model 102: Standard: ±0.2% Full Scale
N Suffix: ±0.5% Full Scale
Model 104: Standard: ±0.2% Full Scale
N Suffix: ±0.5% Full Scale
Model 107: Standard: ±0.2% Full Scale
N Suffix: ±0.5% Full Scale - Pressure Rating:
- Model 101: 100 psig (6.8 bar)
Model 102: 500 psig (34 bar)
Model 104: 500 psig (34 bar)
Model 107: 500 psig (34 bar) - Temperature Rating (Environment):
- Model 101: Operating Range: 5 to 55ºC
Storage Range: 0 to 70ºC
Model 102: Operating Range: 5 to 55ºC
Storage Range: 0 to 70ºC
Model 104: Operating Range: 5 to 55ºC
Storage Range: 0 to 70ºC
Model 107: Operating Range: 5 to 55ºC
Storage Range: 0 to 70ºC - Temperature Sensitivity:
- Model 101: ±0.2% Full Scale or less per ºC Model 102: ±0.2% Full Scale or less per ºC Model 104: ±0.2% Full Scale or less per ºC Model 107: ±0.2% Full Scale or less per ºC
- Wetted Materials:
- Model 101: Ryton
Epoxy
Glass
Sapphire
K suffix: KEL-F
All others: 316 Stainless
Model 102: Brass
Ryton
Epoxy
Glass
Sapphire
Stainless Steel
Model 104: Stainless Steel
Ryton
Epoxy
Glass
Sapphire
Model 107: Stainless Steel
Ryton
Epoxy
Glass
Sapphire - O-Ring Material:
- Model 101: Standard: Viton
Q Suffix: EPDM
Model 102: Standard: Viton
Q Suffix: EPDM
Model 104: Standard: Viton
Q Suffix: EPDM
Model 107: Acetal
Brass
PVDF - Fitting Material:
- Model 101 (Optional): Brass
Stainless Steel
Model 101 (Standard): Acetal
Model 102 (Optional): Acetal
Stainless Steel
PVDF
Model 102 (Standard): Brass
Model 104 (Optional): Acetal
Brass
PVDF
Model 104 (Standard): Stainless Steel - Recommended Filtration:
- Model 101: 25 microns or less
Model 102: 25 microns or less
Model 104: 25 microns or less
Model 107: 25 microns or less - Compatible Liquids:
- Model 101: Low viscosity (<10 cS)
Translucent or transparent
Minimum amount of entrained air
Model 102: Low viscosity (<10 cS)
Translucent or transparent
Minimum amount of entrained air
Model 104: Low viscosity (<10 cS)
Translucent or transparent
Minimum amount of entrained air
Model 107: Low viscosity (<10 cS)
Translucent or transparent
Minimum amount of entrained air - Output Signal:
- Model 101: Non-isolated
2500 ohm minimum load
Model 102:Non-isolated
2500 ohm minimum load
Model 104: Non-isolated
2500 ohm minimum load
Model 107: Standard
Non-isolated
Current loop should not exceed 500 ohms - Power Requirements:
- Model 101: Standard: 12VDC @ 35 mA (11.5-15 VDC)
E Suffix: 24VDC @ 35 mA (18-25 VDC)
Model 102: Standard: 12VDC @ 35 mA (11.5-15 VDC)
E Suffix: 24VDC @ 35 mA (18-25 VDC)
Model 104: Standard: 12VDC @ 35 mA (11.5-15 VDC)
E Suffix: 24VDC @ 35 mA (18-25 VDC)
Model 107: Standard: Viton
Q Suffix: EPDM - Typical Response Time:
- Model 101: Typically <1 second for 63% of final value
Model 102: Typically <1 second for 63% of final value
Model 104: Typically <1 second for 63% of final value
Model 107: Typically <1 second for 63% of final value - Reliability:
- Model 101: 100,000 Hours MTBF
Model 102: 100,000 Hours MTBF
Model 104: 100,000 Hours MTBF
Model 107: 100,000 Hours MTBF - Approvals/Certifications:
- Model 101: CE Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
Model 102: CE Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
Model 104: CE Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
Model 107: CE Approved
89/336/EEC (EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive - Ratings:
- Model 101: Standard: IP10 (NEMA 1)
Y Suffix: IP67 (NEMA 6)
Model 102: Standard: IP10 (NEMA 1)
Y Suffix: IP67 (NEMA 6)
Model 104: Standard: IP10 (NEMA 1)
Y Suffix: IP67 (NEMA 6)
Model 107: Standard: IP10 (NEMA 1)
Y Suffix: IP67 (NEMA 6) - Warranty:
- Model 101: 1 Year Limited Model 102: 1 Year Limited Model 104: 1 Year Limited Model 107: 1 Year Limited
- Pulse Output:
- Model 101: Optional with Suffix T
7.5 VDC peak buffered square wave
±3.0% full scale linearity
0-400 Hz typical
Model 102: Optional with Suffix T
7.5 VDC peak buffered square wave
±3.0% full scale linearity
0-400 Hz typical
Model 104: Optional with Suffix T
7.5 VDC peak buffered square wave
±3.0% full scale linearity
0-400 Hz typical
Model 107: Not available
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|